Add to Cart
GB/T11835 Rock wool,slag wool and its products for thermal insulation Testing Equipment
Product Description:
Product overview: Suitable for rock wool, slag wool, glass wool and products, not for aluminum silicate wool and its products. Under a fixed load, the sample is heated at a certain heating rate to achieve the specified thickness shrinkage rate. The thermal load shrinkage temperature is calculated by interpolation and calculated.
Standard:
GB/T11835
Model: DX8359
Technical parameters:
Ambient temperature | room temperature to 40 ° C |
Relative humidity | ≤75% |
Working voltage | Working voltage |
Heating power | 3500W |
Scale measurement range | room temperature to 900 ° C |
Heating rate | 5 ℃ / min ± 0.3 ℃ and 3 ℃ / min ± 0.2 ℃ can be set |
Dimensions | 1000 × 400 × 1000mm length, width and height |
Temperature controlled heating | 0-800 ℃ |
Implementation method: using a microcontroller or PLC temperature control module to achieve
Heating rate: the rising rate is divided into two sections, normal temperature ~ 700 ℃ and 700 ~ 900 ℃; and the heating rate and the maximum temperature can be set, with an error min ± 0.2 ℃
Thermocouple: K type
Heating furnace: ceramic fiber, chemical resistance, high temperature resistance, long-term use at 1600 ℃, short-term temperature of 1800 ℃, resistance to quenching and heating, not easy to crack, using grouting molding, high density.
Heating furnace wire: nickel 80 chromium 20 alloy wire, temperature resistance 1350 degrees
Heating rate: (50 ℃ -450 ℃) 5 ℃ / min; (450 ℃ -800 ℃) 3 ℃ / min
Main features:
the instrument uses a single-chip computer, multi-point program heating, the heat source uses a hot plate, safe and reliable, long service life, the instrument is equipped with a panel printer to print test results in time.
Installation environment (very important):
Required installation space: 1300 × 700 × 1500mm (length × width × height)
Ambient environment requirements: Keep away from flammable and explosive materials and corrosive liquids and gases
Working environment: 20 ℃ -40 ℃
Test pressure: 490Pa