IEC 60811-504:2012 Mandrel Test Apparatus & Impact Test Apparatus
1. Remark:
The electric low-temperature winding test device is suitable for evaluating and measuring the performance of round cables or round insulated cores at low temperature.
The manual low-temperature impact test device is used to measure the samples of wire and cable insulation and jacket, plugs and sockets, insulating electrical sleeves and accessories for construction. After a specified cooling time, the weight falls from a high place to restore the sample to close to At room temperature, use normal vision to determine whether the sample is cracked.
2.Standard :
Testing apparatus for IEC 60811-504:2012.
3.Technical Parameters:
3.1 Electric low-temperature winding device:
Diameter of winding sample: | Ф2.5~Ф12.5mm |
Diameter of winding rod | Ф4.0~Ф50mm, 12 pieces in total |
Cable bushing | Ф1.2~Ф14.5mm, 10 kinds in total |
The number of sample winding turns | 2 to 10 turns |
Winding speed | 5s/turn |
3.2 Manual low temperature impact device:
Impact height | 100mm |
Weights | 100, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500g |
Number of samples | three |
Voltage | AC220V/50HZ, 20A |
4.Product use conditions:
Ambient temperature:
- 10-28℃;
Relative humidity:
- not more than 85%R.H
Atmospheric pressure:
- 86-106Mpa
- There is no strong vibration around;
- No direct sunlight or direct radiation from other heat sources;
- There is no strong airflow around. When the surrounding air is forced to flow, the airflow should not blow directly onto the box;
- There is no strong electromagnetic field around;
- There is no high concentration of dust and corrosive substances around.
- In order to ensure the normal operation and operation of the equipment, in addition to keeping the equipment horizontally placed, a certain space should be reserved between the equipment and the wall or utensils.