UL817 Protective Mask Tester Carbon Dioxide Volume Test Machine

Ask Latest Price
Video Channel
Brand Name :DAXINA
Model Number :DX8463
Certification :UL817, VDE0620
Place of Origin :China
MOQ :1 set
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram, In cash
Supply Ability :30 sets per month
Delivery Time :30 days after order confirmed
Packaging Details :Standard export wooden case
Stations :6 groups
Load Current :40A/ 12V
Dimension :120×50×148cm
Power :220V, 5A
Power up time :0 ~ 99 min adjustable
Tensile height :254 mm (10 "), 178 mm (7") 2 stalls
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Respiratory Protective Mask Carbon Dioxide (CO2) Volume Test Machine

Description:

The mask dead space detection device is used to detect the dead space of the protective mask, that is, the volume fraction of CO2 in the inhaled gas.

Comply with the standards:

TAJ1001—2015

GB2890-2009

Structure principle:

The main components of the test device include: test head mold, mechanical artificial lung with solenoid valve, connecting pipe, flowmeter, CO2 gas analyzer and control system.


The test device is driven by the low-speed motor of the detection device through the control system to drive the artificial lung to make reciprocating motion to simulate the actual breathing process of human beings. Pushing is equivalent to inhaling, and returning is equivalent to exhaling. In terms of this process, the upper part of the cupboard is completed. At the same time, a certain amount of high concentration CO2 was injected into the breath, and the whole process of respiration was detected by CO2 gas analyzer.

Technical Parameters:

Respiration simulator simulation frequency modulation 10-40 times/min
Adjusting range of simulated tidal volume 0.5~3.0L/min
The volume fraction of carbon dioxide gas source 5.0±0.1%
Carbon dioxide flow meter range not less than 40L/min
Carbon dioxide analyzer range no less than 12%, accuracy no less than 0.1%
Ventilated electric fan wind speed 0.5m/s
Respiratory rate 20 times/min
Respiratory tidal volume 1.5L
Power supply Power supply
Power supply 980mm*820mm*1400mm

Real-time automatic calculation and display of the volume fraction of CO2 in the inhaled gas.

UL817 Protective Mask Tester Carbon Dioxide Volume Test Machine